CLARE MICROBIOLOGICAL CONSULTANTS
11.13 High Street Clare Suffolk CO10 8NY Telephone: Clare (0787) 277244
I.S.HORNSEY - B.Sc., Ph.D., C.Biol., M.I.Biol F.L.S., M.Inst Brewing
E. Coli Removal - Applicable to : DOULTON DRINKING WATER SYSTEM
WITH CU, CS, IMP, SLM, SOV series ceramics
CERTIFICATE OF EFFICIENCY
THIS IS TO CERTIFY THAT FIVE DOULTON STERASYL 10" FILTER CANDLES, MANUACTURED BY FAIREY INDUSTRIAL CERAMICS LTD. ,WERE INSERTED INTO A NP5 FILTER HOLDER AND TESTED FOR BACTERIAL REMOVAL CAPACITY. WHEN INSERTED INTO THE HOLDER THESE CANDLES SHOWED GREATER THAN 99.99% REMOVAL CAPACITY.
THE CHALLENGE WATER WAS INOCULATED WITH 3.60 x 10(4) WASHED VIABLE CELLS OF ESCHERICHIA COLI, WHICH WAS PASSED THROUGH THE FILTER HOLDER AT A RATE OF 3OO LITRES/HOUR. TEST WAS PERFORMED ON 3 DECEMBER 1988.
original signed by
DR. I. S. HORNSEY
CERTIFICATE OF EFFICIENCY
THIS IS TO CERTIFY THAT TW0 DOULTON STERASYL FILTER ELEMENTS, MANUFACTURED BY FAIREY INDUSTRIAL CERAMICS LTD., WERE TESTED FOR BACTERIOLOGICAL REMOVAL CAPACITY AND THAT THEY SHOWED GREATER THAN 99.99% REMOVAL EFFICIENCY.
THE CHALLENGE WATER WAS INOCULATED WITH 1.60x10(4) WASHED VIABLE CELLS OF ESCHERICHIA COLI AND THE UNIT WAS OPERATED AT A FLOW RATE OF 300 LITRES PER HOUR. THE TESTS WERE PERFORMED ON 19 DECEMBER 1988
original signed by
DR. I.S. HORNSEY
Title // Overview // Index // Health // History // Technologies // FAQ // Employment // Training //
// Product Catalog// Travel // Research // Test Results // Orders / Prices // What's New // Contact Us